News

new products

  • TRICONEX 3805E ESD system module in stock, Click for discount price
    TRICONEX 3805E ESD system module in stock, Click for discount price Nov 18, 2020
    TRICONEX TRICON 3805E ESD system module in stock, Click for discount price Any needs,pls feel free to contact E-mail:sales1@swanautomation.com Click Contact: Dora  Phone: 86-15391542482 Wechat:+86-15391542482 +Skype or whatsapp:+86-15391542482 QQ: 1475937454 The TRICONEX system fully complies with the IEC61508/61511 standard, adopts the most advanced TMR microprocessor hardware technology, and the mature and reliable TRISTATION 1131 software triple redundant fault-tolerant control system. The system has high reliability and high utilization rate, and is widely used in petrochemical, oil refining, oil and gas, chemical, electric power, rail transit, aerospace, nuclear industry and other industries. It is used in equipment safety interlocking system ESD, steam turbine control, and steam turbine control. It has extensive achievements in level control, compressor anti-surge control, offshore oil platform, fire and gas monitoring and protection (F&G), etc. Typical application of IPS TRICONEX safety control system Safe emergency stop (ESD)            The safety system can provide continuous protection for safety-critical units in oil refining, petroleum, chemical and other industrial processes, such as reactors and compressor units, and perform various trip signals-pressure, product feed, expander pressure balance and temperature, etc. Monitor and stop safely when necessary. Traditional emergency shutdown systems use mechanical or electronic relays to achieve shutdown protection, but this often causes dangerous false trips. The TRICONEX system has parking and control functions, can conduct temporary testing and verification of on-site sensors, and can be directly connected with DCS or other upper computers for continuous monitoring. TRICONEX TRICON 8100-8 main frame TRICONEX TRICON 8307A Expansion/RXM rack power supply, 230VAC TRICONEX TRICON 8101 expansion rack TRICONEX TRICON 8305A Expansion/RXM rack power supply, 115VAC/DC TRICONEX TRICON 8102 remote expansion rack TRICONEX TRICON 8306A extension/RXM rack power supply, 24VDC TRICONEX TRICON 8306A I/O bus extension cable TRICONEX TRICON 4400 Safety Management Module (SMM) TRICONEX TRICON 9001 I/O communication bus extension cable TRICONEX TRICON 4508 High Speed Channel Interface Module (HIM) TRICONEX TRICON 8105 I/O empty slot board TRICONEX TRICON 8306A extension/RXM rack power supply, 24VDC TRICONEX TRICON 8106 Empty terminal slot board TRICONEX TRICON 4328 Network Communication Module (NCM) TRICONEX TRICON 8302A main frame power supply, 230VAC TRICONEX TRICON 4400 Safety Management Module (SMM) TRICONEX TRICON 8300A main frame power supply, 115VAC/DC TRICONEX TRICON 4508 High Speed Channel Interface Module (HIM) TRICONEX TRICON 8301A main frame power supply, 24VDC TRICONEX TRICON 7518-1 communication network module/ISA bus TRICONEX TRICON 8310 control system power supply 120VAC/VDC TRICONEX TRICON 4108 Enhanced Intelligent Communication Module ...
    Read More
  • ABB PM864AK01 3BSE018161R1 AC 800M CPU Module in stpck,Click for discount
    ABB PM864AK01 3BSE018161R1 AC 800M CPU Module in stpck,Click for discount Nov 18, 2020
    ABB PM864AK01 3BSE018161R1 AC 800M CPU Module Detail information Any needs,pls feel free to contactE-mail:sales1@swanautomation.com click Contact: Dora  Phone: 86-15391542482 Wechat:+86-15391542482 +Skype or whatsapp:+86-15391542482 QQ: 1475937454 The CPU board contains the microprocessor and RAM memory, a real-time clock, LED indicators, INIT push button, and a CompactFlash interface. The base plate of the PM864A controller has two RJ45 Ethernet ports (CN1, CN2) for connection to the Control Network, and two RJ45 serial ports (COM3, COM4). One of the serial ports (COM3) is an RS-232C port with modem control signals, whereas the other port (COM4) is isolated and used for the connection of a configuration tool. The controller supports CPU redundancy for higher availability (CPU, CEX-Bus, communication interfaces and S800 I/O). Simple DIN rail attachment / detachment procedures, using the unique slide & lock mechanism. All base plates are provided with a unique Ethernet address which provides every CPU with a hardware identity. The address can be found on the Ethernet address label attached to the TP830 base plate. Features and benefits Reliability and simple fault diagnosis procedures Modularity, allowing for step-by-step expansion IP20 Class protection without the requirement for enclosures The controller can be configured with 800xA control builder The controller has full EMC certification Sectioned CEX-Bus using a pair of BC810 Hardware based on standards for optimum communication connectivity (Ethernet, PROFIBUS DP, etc.) Built-in redundant Ethernet Communication ports PM860K01 3BSE018100R1 PM861AK01 3BSE018157R1 PM861AK02 3BSE018160R1 PM864AK01 3BSE018161R1 PM864AK02 3BSE018164R1 PM866K01 3BSE050198R1 PM866K02 3BSE050199R1 SB821 3BSE018109R1 SB822 3BSE018172R1 PM865K01 3BSE031151R1 PM865K02 3BSE031150R1 SM810K01 Safety CPU Module Kit SM810K01 3BSE030928R1 SS823 3BSE038226R1 TK212A 3BSC630197R1 TC562 3BSC630049R1 TK853V020 3BSC950201R1 CI853K01 3BSE018103R1 CI854AK01 3BSE030220R1 CI860K01 3BSE032444R1 CI855K01 3BSE018106R1 CI856K01 3BSE026055R1 CI862K01 3BUA000037R1 CI865K01 3BSE040795R1 CI857K01 3BSE018144R1 CI858K01 3BSE018135R1 TK850V007 3BSC950192R1 TB850 3BSC950193R1 TB851 3BSC950194R1 TK851V010 3BSC950262R1 TB852 3BSC950263R1 BC810K02 3BSC031155R1
    Read More
  • ABB PM891K01 3BSE053241R1 DCS Redundant controller Click for discount
    ABB PM891K01 3BSE053241R1 DCS Redundant controller Click for discount Nov 18, 2020
    ABB PM891K01 3BSE053241R1 Detail information Any needs,pls feel free to contactE-mail:sales1@swanautomation.com click Contact: Dora  Phone: 86-15391542482 Wechat:+86-15391542482 +Skype or Whatsapp:+86-15391542482 QQ: 1475937454 The PM891 processor is a monolithic unit equipped with power supply, CPU-boards and unit termination. The unit contains microprocessor and RAM memory, a real-time clock, LED indicators, INIT push button and a Secure Digital interface. The PM891 does not contain any internal battery The PM891 has two RJ45 Ethernet ports (CN1, CN2) for connection to the Control Network, and one RJ45 serial port (COM4). The COM4 port is isolated and used for a configuration tool. The PM891 supports CPU redundancy for higher availability (CPU, CEX-Bus, communication interfaces and S800 I/O). The communication expansion bus (CEX-Bus) is mounted on the unit. The CEX-Bus is used for extending the on-board communication ports with communication interface units. It is possible to use redundant communication interfaces on the CEX-Bus. The CEX-Bus Interconnection unit BC810 is used to increase the availability on the CEX-Bus by dividing it into separate segments. The optical Modulebus of the unit can be used for connecting seven clusters of S800 I/O units (each comprising up to 12 units). Each PM891 is provided with a unique Ethernet address which provides hardware identity to the unit. Features and benefits Reliability and simple fault diagnosis procedures Modularity, allowing for step-by-step expansion IP20 Class protection without the requirement for enclosures The controller has full EMC certification High performance and large application memory Sectioned CEX-Bus using a pair of BC810 Built-in redundant Ethernet Communication ports PM851K01 3BSE018168R1 PM856K01 3BSE0181048R1 PM860K01 3BSE018100R1 PM861AK01 3BSE018157R1 PM861AK02 3BSE018160R1 PM864AK01 3BSE018161R1 PM864AK02 3BSE018164R1 PM866K01 3BSE050198R1 PM866K02 3BSE050199R1 SB821 3BSE018109R1 SB822 3BSE018172R1 PM865K01 3BSE031151R1 PM865K02 3BSE031150R1 SM810K01 Safety CPU Module Kit SM810K01 3BSE030928R1 SS823 3BSE038226R1 TK212A 3BSC630197R1 TC562 3BSC630049R1 TK853V020 3BSC950201R1 CI853K01 3BSE018103R1 CI854AK01 3BSE030220R1 CI860K01 3BSE032444R1 CI855K01 3BSE018106R1 CI856K01 3BSE026055R1 CI862K01 3BUA000037R1 CI865K01 3BSE040795R1 CI857K01 3BSE018144R1 CI858K01 3BSE018135R1 TK850V007 3BSC950192R1 TB850 3BSC950193R1 TB851 3BSC950194R1 TK851V010 3BSC950262R1 TB852 3BSC950263R1 BC810K02 3BSC031155R1
    Read More
  •  ABB  AC 800PEC PP D113 B01-25-111000 3BHE023784R2530 in stock,click for discount price
    ABB AC 800PEC PP D113 B01-25-111000 3BHE023784R2530 in stock,click for discount price Nov 18, 2020
    ABB AC 800PEC PP D113 B01-25-111000 3BHE023784R2530 in stock, click for discount price Any needs,pls feel free to contactE-mail:sales1@swanautomation.com Click Contact: Dora  Phone: 86-15391542482 Wechat:+86-15391542482
    Read More
  • Rockwell Trusted TMR ICS T8461,  T8461C Digital Output Module in stock Advantage price
    Rockwell Trusted TMR ICS T8461, T8461C Digital Output Module in stock Advantage price Oct 30, 2020
    ★A large number of stocks  ★Integrity supply  ★ Advantage price Contact: Dora     Wechat:+86-15391542482  +Skype or whatsapp:+86-15391542482 E-mail:sales1@swanautomation.com Click   QQ: 1475937454 Trusted T6300 is a system based on a triple processor, all important internal circuits are designed with triple fault tolerance. Trusted T6300 guarantees that the system can still execute the program correctly in the case of an internal failure. All modules of the system can be hot replaced online. This design allows the Trusted T6300 system to remain almost 100% online. Trusted T6300 is used to control various complex and dangerous production processes in real time, accept field signals, execute logic operations, PID and other control programs, output control signals, and drive field execution units. Trusted's application program is compiled with IEC 61131 TOOLSET software. The Trusted T6300 performs the above operations continuously and at high speed to achieve fast closed-loop data processing. If an internal fault occurs in the Trusted system, the fault will be limited by the voting unit. The widely distributed voting chips in the system ensure that any internal faults in the system will not be propagated to the program processing process, and can accurately indicate the location of the system's internal faults. Each register and program controller vote in the same way. All internal communications have a receiving circuit for communication verification. T8403 Trusted TMR 24Vdc Digital Input Module T8403C Trusted TMR 24Vdc Digital Input Module T8311C Trusted TMR Module   T8431 Trusted TMR Analogue Input Module T8431C Trusted TMR Analogue Input Module   T8480 Trusted TMR Analogue Output Module T8442 Trusted TMR Module   T8461 Trusted TMR 24 48Vdc Digital Output Module T8461C Trusted TMR 24 48Vdc Digital Output Module   T8451 Trusted TMR 24Vdc Digital Output Module   T8433 Trusted TMR Isolated Analogue Input Module T8423 Trusted TMR 35 - 120Vdc Digital Input Module   T8402 Trusted Dual 24Vdc Digital Input Module   T8424 Trusted TMR 120Vac Digital Input Module   T8473 Trusted TMR 120Vac Isolated Digital Output Module   T8471 Trusted TMR 120Vdc Digital Output Module   T8448 Trusted TMR 24Vdc Zone Interface Module   T8432 Trusted Dual Analogue Input Module   T8472 Trusted TMR 120VAC Digital Output Module   T8100 Trusted TMR Controller Chassis   T8110B Trusted TMR Processor T8111C  Trusted TMR Module T9451 Trusted TMR Module
    Read More
First << 1 ... 15 16 17 18 19 20 21 22 >> Last
[  A total of  22  pages]
Leave a message

Leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

News

Contact

top