The KL9508 power supply terminal generates an output voltage of 8 V DC from the (24 V DC) input voltage, which can be accessed at the terminal. The following Bus Terminals are also supplied with this voltage via the power contacts. The power LEDs indicate the terminal’s operating state. The input voltage and the output voltage U0 are not electrically isolated.
The KL9510 power supply terminal generates an output voltage of 10 V DC from the (24 V DC) input voltage, which can be accessed at the terminal. The following Bus Terminals are also supplied with this voltage via the power contacts. The power LEDs indicate the terminal’s operating state. The input voltage and the output voltage U0 are not electrically isolated.
The KL9510 power supply terminal generates an output voltage of 10 V DC from the (24 V DC) input voltage, which can be accessed at the terminal. The following Bus Terminals are also supplied with this voltage via the power contacts. The power LEDs indicate the terminal’s operating state. The input voltage and the output voltage U0 are not electrically isolated.
The KL9512 power supply terminal generates an output voltage of 12 V DC from the (24 V DC) input voltage, which can be accessed at the terminal. The following Bus Terminals are also supplied with this voltage via the power contacts.
The KL9515 power supply terminal generates an output voltage of 15 V DC from the (24 V DC) input voltage, which can be accessed at the terminal. The following Bus Terminals are also supplied with this voltage via the power contacts.
The KL9540 system terminal contains an overvoltage filter for the 24 V field supply. The filter protects the Bus Terminal from line-bound surge voltages that can occur due to high-energy disturbances such as switching overvoltages at inductive consumers or lightning strikes at the supply lines.
The KL9550 system terminal contains an overvoltage filter for the 24 V field and system supply. The filter protects the Bus Terminal from line-bound surge voltages that can occur due to high-energy disturbances such as switching overvoltages at inductive consumers or lightning strikes at the supply lines.
he KL9560 power supply unit terminal generates an electrically isolated output voltage from the 24 V DC input voltage, which can be accessed at the terminal. The following Bus Terminals are also supplied with this voltage via the power contacts.
The module is a digital output module with phase-angle control that is equipped with 4 Triac outputs using 2-line connections. The supply (L and N) is fed directly to the module.
The module is a digital output module that is equipped with 4 SSR outputs with zero cross-over switches and uses 2-line connections. The module is also equipped with integrated full-wave control. The supply (L and N) is fed directly to the module.
The module is a digital output module that is equipped with 4 opto-triac outputs using phase-angle control. L and N are fed to the module for zero-crossing detection.